After Sales
Technical Documentation
RAE/RAK–1N
Baseband
Page 2–26
Original, 08/96
CTRLU – ACCESSORIES
MBUS is used to control external accessories. This interface can also be
used for factory testing and maintenance purposes.
There are also some control and indication signals for the accessories:
JCONN is used to indicate that junction box is connected. JCONN is
actually the DC–level of the EXTMIC signal. Phone can also enter
minimum mode when MBUS is connected to EXTMIC line.
Main components
Hitachi H8/538
H8/538 is a CMOS microcontroller unit (MCU) which includes a static CPU
core and on–chip supporting modules with 16–bit architecture. The data
bus to outside world is 16 bits wide.
SCL ASIC
MCU address decoding and memory chip select generation
FLASH and system ASIC address mapping
MBUS interface
MBUS/RBUS activity detection
MCU clock division from 26 MHz to 13 MHz
512k*16bit FLASH memory
two 512Kx8 FLASH chips
65 ns maximum read access time
contains the main program code for the MCU; part of the DSP pro-
gram code also located on FLASH
64k*16bit SRAM memory
two 64Kx8 SRAM chips
65 ns maximum read access time
8k*8bit EEPROM memory
150 ns maximum read access time
contains user defined information
PWRU
Introduction
The power block creates the supply voltages for the baseband block and
contains the charging switch and its control electronics.
Technical description
Table 29. External Signals and Connections, Inputs
Signal Name Signal description From
XPWRON Power on switch B2B Conn
XPWROFF PSL+ watchdog updating; power off control CTRLU
VBATT Battery voltage Battery conn