4 Analog line
5 Analog line
6 Not used
7 Not used
8 Not used
Power supply connector:
Pin Description
1 26V AC
2 26V AC
8.8.3.3 Power Supply Details
The power supply unit depends on country:
Reference Characteristics Country
1AF01101BAAA 230V AC/26V AC 130mA Europe
1AF01101DAAA 230V AC/26V AC 130mA UK
1AF01101AAAA 115V AC/26V AC 130mA USA
8.8.3.4 Environment
Working temperature: 5°C to 45°C
Stocking temperature: -40°C to 70°C
Relative humidity: 5% to 85%
8.9 S0 Interface Module
8.9.1 Hardware description
8.9.1.1 Overview
The S0 Interface Module allows an S0 bus (2 B + 1 D channels) to be connected to the OXO Connect
via a UA link. This bus allows S0 terminals (S0 sets, PCs equipped with an S0 interface, Fax G4,
modem, etc.) to be connected.
The S0 Interface Module can be used alone or combined with Digital Premium DeskPhones.
Chapter
8
Device commissioning
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual 150/216