B2
B1
B1
Step a
Step b (if required)
-
+
-
+
-
+
4. Connect the positive (red) terminals of the batteries as described below (and shown in the figure
below). Note that there may be a small amount of electrical arcing when electrical contact is made.
a. Connect the middle connector of the red wire to the positive (red) terminal of battery B1.
b. If required, connect the end connector of the red wire to the positive (red) terminal of battery B2.
B2
B1
B1
Step a
Step b (if required)
-
+
-
+
-
+
5. Close the unit and secure it with the four screws.
6. Stick a label on the unit stating the date of the installation and the number of batteries installed.
4.3.3.5.2 Connecting to the OXO Connect Compact Platform
1. Switch off the OXO Connect system and then:
a. Unplug the power cable from the mains socket.
b. Disconnect the mains adapter from the OXO Connect Compact platform.
c. Using a screwdriver, unscrew the power supply module (PSXS or PSXS-N) from the side of the
OXO Connect Compact platform and pull the module out of the cabinet.
2. Move the red extBAT jumper from the NO position to the YES position.
Chapter
4
Powering and connecting the PBX to the customer LAN
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual 65/216