4.2.4 Connection of PowerCPU EE C25 Board
PROCESSING UNIT
Power MEX
Power MEX
ETHERNET LANSWITCH
LanX8-2
12V serviceable voltage
External LAN Switch
PC (OMC, NMC)
Doorphone
Power MEX board (extension unit) 1
Power MEX board (extension unit 2)
PowerCPU EE board
LanX-2 board
MODULE EXPANSION
MODULE EXPANSION
Background music
Loudspeaker
Alarm
"Please wait" message
Power CPU EE C25
4.2.5 Connecting Terminals
4.2.5.1 Connecting Digital Terminals
The terminals are equipped with a cable and a self-acting switch that plugs into the wall socket. Each
terminal is connected up by a pair of 0.5 or 0.6 mm diameter wires.
System - digital terminal distances:
0.5 mm SYT type cable: 800 m (station without option) or 600 m (station with S0 or Z option).
278 type 0.6 mm cable: 1200 m (station without option) or 850 m (station with S0 or Z option).
Chapter
4
Powering and connecting the PBX to the customer LAN
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual 45/216