13
4.2.5
Displaying "SNR xxxx" during Automatic System
Possible Cause(s) Suggested Solution(s)
a) Improper sensor
alignment
NOTE:
Sensor is not reading the
ground or the target properly
a) Check sensor alignment (Section 6),
primarily the sensor involved with the
error. For example, if the System Setup is
performing a "LftDet" and this message
appears, check the Left wing sensor(s).
b) Poor targets such as
wet gravel or stubble
b) Try a different target.
4.2.6 Sensor Swapping
Swapping Sensors is a useful procedure for determining whether a sensor
error message (e.g. "LO NR") is due to the sensor or the wiring to the
sensor.
NOTE: A sensor may have power and emit a ticking sound, but have broken
communication wire(s), which would cause this error. Performing Sensor
Swapping would help determining the cause.
The procedure is as follows:
i) Exchange the affected sensor with one that is reporting correctly
(e.g. "LO" and "RO").
ii) Swap (input) their respective location serial numbers into the control
panel (Refer to Section 8.5.3.1.1 “Entering Sensor Serial
Numbers” in the UC4 Technical Manual).
iii) If the problem still exists in the same location ("LO NR"), and the
sensor on the "RO" is reporting correctly, the wiring from the left
outer ("LO") branch may have a fault and the sensor itself is
functional.
iv) If the error appears on the right outer sensor ("RO NR"), the sensor
may not be functioning.