NORAM 65ET GRADER
4-35
Lubrication and Maintenance - Grader Components
4
Every 1000 Hours or 6 Months
Procedure to start AEB:
NOTE: AEB will not start with any fault codes on display except fault “F6”.
1. Warm up transmission.
The message “Normal operating messages” is displayed.
2. Stop engine.
3. Turn on key switch.
4. Scroll through display to AEB.
NOTE: From main screen press Menu, select System Settings, then select AEB Mode Request.
5. Move shift lever to N position.
6. Engage park brake.
7. Start engine
8. Set engine speed to 800 rpm.
9. Press button of the display to start AEB.
The message “ST” is displayed if the start conditions are ok.
NOTE: The button must not be released before TCU has started the AEB or quit with an error
code.
10. Hold button until AEB has started.
The message “K1” will be displayed. (Information about the AEB state)
NOTE: TCU has started the AEB and goes on adjusting K1, K2, ..., KR. (Button may be released)
11. Wait until AEB has finished.
The message “OK” will be displayed. AEB has been successful.