3.6 Fitting push-on gear units with fastening element (option: B)
WARNING
Risk of severe injuries
If the screw fastenings of the torque arm are removed during operation, the gear unit will rotate
around the output shaft.
Secure the screw fastening against loosening, e.g. with Loctite 242 or a second nut.
NOTICE
The gear unit may be damaged by axial forces.
Bearings, gearwheels, shafts and housings may be damaged by incorrect fitting.
Use a suitable pulling device.
Do not strike the gear unit with a hammer.
Assembly and subsequent dismantling is facilitated by applying an anti-corrosive lubricant to the shaft
before fitting (e.g. NORD Anti-Corrosion Part No. 089 00099). Excess lubricant may escape after
fitting and may drip off. This escape of grease is not due to a leak in the gear unit. Thoroughly clean
these points on the output shaft after a running-in time of approx. 24 hours.
Figure 4: Applying lubricant to the shaft and the hub
For push-on gear units with cover cap IP66 (Option H66) and fastening element (Option B) the
pressed-in closing cap must be pushed out before installing the gear unit. The pressed-in closing cap
may be destroyed during dismantling. A 2nd closing cap is supplied as a spare part. Fit the closing
cap after installation of the gear unit as described in Section 3.9 "Fitting the covers (option: H, H66)".