Gear units – Manual with installation instructions
70 B 1000 en-3921
Lubri-
cant
type
Details on
name plate
DIN (ISO) /
Ambient
temperature
CLP PG H1
680
ISO VG 680
-5…40 °C
Optileb GT
1800/680
Cassida Fluid WG
680
Klübersynth
UH1 6-680
Mobil
Glygoyle 680
CLP PG H1
220
ISO VG 220
-25…40 °C
Optileb GT
1800/200
Cassida Fluid WG
220
Klübersynth
UH1 6-220
Mobil
Glygoyle 220
Nevastane SY
220
CLP HC H1
680
ISO VG 680
-5…40 °C
Optileb GT 680
Cassida Fluid GL
680
Klüberoil
4 UH1-680 N
-
CLP HC H1
220
ISO VG 220
-25…40 °C
Optileb GT 220
Cassida Fluid GL
220
Klüberoil
4 UH1-220 N
Mobil
SHC Cibus
220
Nevastane
XSH 220
-
based
GP 00 K-30
-25 … 60 °C
PD
Tribol GR
3020/1000-00 PD
Spheerol EPL 00
Renolit Duraplex
EP 00
MICROLUBE
GB 00
Mobil
Chassis
Grease LBZ
Alvania
EP(LF)2
Multis EP 00
PG oil
GP PG 00 K-
30
Renolit
LST 00
Klübersynth
GE 46-1200
Mobil
Glygoyle
Grease 00
- Marson SY 00
Table 12: Gear oils
The required lubricant quantity and the lubricant type are stated on the name plate. The filling
quantities stated in the catalogue G1000 are for guidance only. The precise quantities vary depending
on the exact gear ratio. When filling, always observe the oil level screw hole as an indicator of the
precise quantity of oil.
After changing the lubricant, and in particular after the initial filling, the oil level may change during the
first few hours of operation, as the oil galleries and the hollow spaces only fill gradually during
operation. The oil level is still within the permissible tolerance.
If the gear unit contains an oil inspection glass, we recommend that the customer adjusts the oil level
after an operating time of 2 hours so that the oil level is visible in the oil inspection glass when the
gear unit is at a standstill and has cooled down. An oil level check with the oil inspection glass is only
possible after this time.
Gear unit types SK 11282, SK 11382, SK 11382.1, SK 12382 and SK 9096.1 are normally supplied
without oil.