42 B 1000 en-3921
Procedure:
1. Loosen and remove the cap screws.
2. Remove the cartridge cover.
3. Screw the activation screw into the lubricant dispenser until the lug breaks off at the defined
fracture point.
4. Re-fit the cartridge cover. Attach the cartridge cover with the cap screws (see chapter 7.3 "Screw
tightening torques").
5. Mark month and year of activation on the adhesive label.
Explanation
1
Cap screws M8 x 16
2 Cartridge cover
3
Activation screw
4
Lug
5
Lubricant sensor
6
Position of adhesive label
Figure 24: Activating the automatic lubricant sensor with standard motor mounting
Adhesive label
Figure 25: Adhesive label
4.4 Cooling coil (Option: CC)
NOTICE
Gear unit damage due to overheating
The drive may only be commissioned after the cooling spiral has been connected to the cooling
circuit, and the cooling circuit has been put into operation.
If there is a danger of frost, a suitable anti-freeze solution must be added to the cooling water in due
time.
The coolant must have a thermal capacity similar to water.
Specific thermal capacity of water at 20 °C: c = 4.18 kJ/kgK