NORDAC SK 200E Manual
68 Subject to technical alterations BU 0200 GB
3.4.2 Potentiometer Adapter, SK CU4-POT
The digital signals R and L can be directly applied to the corresponding digital inputs 1 and 2 of the SK 200E.
The potentiometer (0-10) can be evaluated via a 24V module or I/O extension and converted to proportional
impulses (frequency). These impulses can then be evaluated via the digital input 2 or 3
(P420 [02]/[03] = 26/27) of the SK 200E in the form of a setpoint value (P400 [-06]/[-07]).
Module
Connection: Terminal
No.
Pin
Colour
SK CU4-POT
FI Mains unit
Function
1
Brown
24V supply voltage 44
2
Black
Enable R (e.g. DIN 1) 21
3
White
Enable L (e.g. DIN2) 22
Rotary switch L - OFF - R
4
White
Access to AIN1+ 14
5
Brown
10V reference voltage 11
6
Blue
Analog Ground AGND 12
Potentiometer 10k