Refer to Table A 4-1. Use this procedure to program the SYSTEM
SETTINGS features.
1. See Figure A 4-2. Press the Move Up and Move Down keys (4) until
the SYSTEM SETTINGS light turns on.
NOTE: If you have enabled the password feature, you must change
the number in the Multipurpose display (500) to the password (321)
and press the Enter key before the system will allow you to change any
SYSTEM SETTINGS features.
2. Refer to Table A 4-2 to determine which SYSTEM SETTINGS feature
to customize.
WARNING: Risk of fire. The default for the overtemperature
setpoint is 204 _C (400 _F). If the Safety Data Sheet (SDS) for
your adhesive gives a flash point that is below 218 _C (425 _F),
be sure to reset the overtemperature setting to at least 42 _C
(75 _F) below the flash point.
3. See Figure A 4-2. Press the Up key (1) until the number of the feature
you want appears in the Selector display (2). As the feature number
changes, the Multipurpose display (3) changes to show the setting of
each feature selected.
4. Press the Up or Down keys (4) to change the setting. The
Multipurpose display flashes.
5. Press the Enter (5) key to save the new setting. The Multipurpose
display stops flashing.
4130012
2
3
4 5
1
Fig. A 4-2 Changing the Setting of a Selected Feature
1. Up key
2. Selector display
3. Multipurpose display
4. Up and Down keys
5. Enter key