LA 404 Pattern Control System
27
Part 1037527B
! 2005 Nordson Corporation
Manual 66-LA404-MA-01
Trigger Assignment
In this menu each of the four channels can be activated and assign one of
the four trigger inputs.
GE=<<?F!H1!!!!!!!!!%9:;I? !
$5;JJ?5!%KK;J<A?<:
$5;JJ?5!!!!!!!!!!!!1
6640010A
1. To select Channel number’s 1 – 4, press the CHANNEL SELECT button
on the front panel of the patten controller.
2. To set channel 1 to ACTIVE or INACTIVE:
a. Press the % or & button for the cursor to appear beside ACTIVE or
INACTIVE.
b. Press the " or # button to select ACTIVE or INACTIVE.
3. To assign triggers 1 – 4 to a channel:
a. Press the % or & button for the cursor to appear beside the numeric
value.
b. Press the " or # button to select from trigger numbers 1 – 4.
NOTE: The assigned trigger number will be displayed in the Trigger
Settings menu.
4. Repeat steps 2 – 3 to set Channel number’s 2 – 4.