LA 404 Pattern Control System
30
Part 1037527B
! 2005 Nordson Corporation
Manual 66-LA404-MA-01
Pressure 1 and 2 Settings (contd)
45?KK85?!1!+?::;<JK
+>??7!1 @
!!!!!41!!!!@N
+>??7!2 /!!!!!42!!!!O@N
*;<!@N !*=P!!!1@@N
6640012A
1. To set speed 1:
a. Press the % or & button for the cursor to appear beside the numeric
value.
b. Press the " or # button to set the desired speed value from
0 – 599 m/min.
2. To set P1:
a. Press the % or & button for the cursor to appear beside P1’s
numeric percentage value.
b. Press the & button to set P1 from 0 – 100%.
3. To set speed 2:
a. Press the % or & button for the cursor to appear beside the numeric
value.
b. Press the " or # button to set the desired speed value from
1 – 600 m/min.
4. To set P2:
a. Press the % or & button for the cursor to appear beside P2’s
numeric percentage value.
b. Press the & button to set P2 from 0 – 100%.
5. To set minimum and maximum pressure:
a. Press the % or & button for the cursor to appear beside either Min
or Max.
b. When the cursor appears beside Min, press the " or # button to set
the desired percentage value from 0 – 99%.
c. When the cursor appears beside Max, press the " or # button to
set the desired percentage value from 1 – 99%.
6. Press the SET UP forward button to go to Pressure 2 Settings, and then
repeat steps 1 – 5.