LA 404 Pattern Control System
32
Part 1037527B
! 2005 Nordson Corporation
Manual 66-LA404-MA-01
Channel Compensation (contd)
GE=<!H!1! G6A>?<K=:;6<
48FFQ;<!!!!!!! ! ! @@0@!AA
)56>Q68:!!!!!! ! ! @@0@!AA
+?:!K>??7!!!!!!3@AB A ; < !
!
6640014A
1. To select Chan (channel) number’s 1 – 4, press the CHANNEL SELECT
button on the front panel of the patten controller.
2. To set pull-in:
a. Press the % or & button for the cursor to appear beside the numeric
value.
b. Press the " or # button to set the desired pull-in value from
00.0 – 500.0 mm.
NOTE: Pull-in is the amount of time prior to start of a bead.
3. To set drop-out:
a. Press the % or & button for the cursor to appear beside the numeric
value.
b. Press the " or # button to set the desired drop-in value from
00.0 – 500.0 mm.
NOTE: Drop-out is the amount of time prior to the finish of a bead.
4. To set speed:
a. Press the % or & button for the cursor to appear beside the numeric
value.
b. Press the " or # button to set the desired value from
1 – 600 m/mm.
5. Repeat steps 2 – 4 to set Chan (channel) number’s 2 – 4.