LA 404 Pattern Control System
37
Part 1037527B
! 2005 Nordson Corporation
Manual 66-LA404-MA-01
NOTE: Interval (also known as pitch) is the distance from the start of one
bead to the start of the next bead.
*678F=:?7!R?=7
+>??7! !!!@!ABA;<
"<:?5I=F !!!/!AA!
!
6640018A
1. To set speed:
a. Press the % or & button for the cursor to appear beside the numeric
value.
b. Press the " or # button to set the desired speed value from
0 – 600 m/min.
2. To set interval:
a. Press the % or & button for the cursor to appear beside the numeric
value.
b. Press the " or # button to set the desired interval value from
3 – 9999 mm.
3. After setting the Speed and Interval, press the SET UP forward button to
open the Dly/Dur setup menu screen, refer to Normal Beads.
4. To set Dly:
a. Press the % or & button for the cursor to appear beside the numeric
value.
b. Press the " or # button to to set the desired delay value from
0 – 8187 mm.
5. To set Dur:
a. Press the % or & button for the cursor to appear beside the numeric
value.
b. Press the " or # button to set the desired duration value from
0 – 8192 mm.