LA 404 Pattern Control System
39
Part 1037527B
! 2005 Nordson Corporation
Manual 66-LA404-MA-01
+:;:9E?7!R?=7
(F8?!+=I;< JK !!!!!!T@N
"<:?5I=F !!!!!!/!AA!
!
6640019A
1. To set glue savings:
a. Press the % or & button for the cursor to appear beside the numeric
percentage value.
b. Press the " or # button to set the desired glue savings value from
10 – 90%.
2. To set interval:
a. Press the % or & button for the cursor to appear beside the numeric
value.
b. Press the " or # button to set the desired Interval value from
3 – 9999 mm.
3. After setting the Glue Savings and Interval, press the SET UP forward
button to open the Dly/Dur setup menu screen, refer to Normal Beads.
4. To set Dly:
a. Press the % or & button for the cursor to appear beside the numeric
value.
b. Press the " or # button to to set the desired delay value from
0 – 8187 mm.
5. To set Dur:
a. Press the % or & button for the cursor to appear beside the numeric
value.
b. Press the " or # button to set the desired duration value from
0 – 8192 mm.