LA 404 Pattern Control System
54
Part 1037527B
! 2005 Nordson Corporation
Manual 66-LA404-MA-01
System Settings 2 (contd)
3. To enable remote recall:
a. Press the % or & button for the cursor to appear beside On/Off.
b. Press the " or # button to select On or Off.
NOTE: When remote recall is on programs cannot be selected from the
front panel.
Remote Recall Program Table
Use the table to access programs remotely. Also refer to Remote Input pin
information under I/O Connector Pin Layout given earlier.
Program Number Remote Recall 4 Remote Recall 3 Remote Recall 2 Remote Recall 1 Remote Recall 0
0 0 0 0 0 0
1 0 0 0 0 24 V
2 0 0 0 24 V 0
3 0 0 0 24 V 24 V
4 0 0 24 V 0 0
5 0 0 24 V 0 24 V
6 0 0 24 V 24 V 0
7 0 0 24 V 24 V 24 V
8 0 24 V 0 0 0
9 0 24 V 0 0 24 V
10 0 24 V 0 24 V 0
11 0 24 V 0 24 V 24 V
12 0 24 V 24 V 0 0
13 0 24 V 24 V 0 24 V
14 0 24 V 24 V 24 V 0
15 0 24 V 24 V 24 V 24 V
16 24 V 0 0 0 0
17 24 V 0 0 0 24 V
18 24 V 0 0 24 V 0
19 24 V 0 0 24 V 24 V
20 24 V 0 24 V 0 0
21 24 V 0 24 V 0 24 V
22 24 V 0 24 V 24 V 0
23 24 V 0 24 V 24 V 24 V
24 24 V 24 V 0 0 0
25 24 V 24 V 0 0 24 V
26 24 V 24 V 0 24 V 0
27 24 V 24 V 0 24 V 24 V
28 24 V 24 V 24 V 0 0
29 24 V 24 V 24 V 0 24 V
30 24 V 24 V 24 V 24 V 0
31 24 V 24 V 24 V 24 V 24 V