14. Self-learning of the stroke
WARNING 1: when a stroke self-learning operation is carried out, be sure that there is
no obstacle on the run (e.g., execute a manual open/close operation of the garage door).
ATTENZIONE 2: In case of alarm or intervention of a protection (in case of photocells in-
stalled and configured via parameter
) lthe learning procedure will be interrupted and
the alarm code will be shown on the display (in case of intervention of a photocell will
be shown). Restart the learning procedure by pressing
ESC
, the system will return to .
NOTE 1: If the procedure is in progress (step or over) and you want interrupt it,
press
ESC
. The motor will stop and the learning restarts from the step .
NOTE 2: in case you want have access to menu to change some parameters value you
must exit from learning procedure pressing
ESC
key for few seconds till the display visua-
lizes
.
Once the setting is complete, it is possible to return to the self-learning procedure by
pressing
ESC
repeatedly until you exit the menu and return to . If it is not possible to
return to , press the
ENTER
+
ESC
pbuttons simultaneously for about 4 seconds to perform
a reset of the learning procedure