EasyManua.ls Logo

Notifier ACM-16AT User Manual

Notifier ACM-16AT
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background image
Installation, Configuration, and Programming
38 PN 15842:K 7/23/2002
4.12.4 Speaker Control Mode
ACM-24AT boards provide a Speaker Control Mode for use with XPIQ or
control modules. This is available for the following panels: AFP-300/AFP-400,
AFC-600, NFS-640, NFS-3030, NCA, and AM2020/AFP1010. Note: The
XPIQ can only support up to four channels.
The board switches are grouped depending on the number of channels, so that
the number of switches per group equals the number of channels enabled on the
XPIQ. This enables the ACS to control operation of groups of multi-channels
mapped to groups of multiple speakers. Within a group, channels have priority
and only one channel can output its contents on the speaker circuit. Pressing a
switch in a group has the following effects:
1. If there are no lit LEDs in the group, the output of the channel will be
directed to the speaker circuit, and the point-active LED at that switch will
flash.
2. If the LED is unlit but other outputs within the group are active, the
other outputs will be deactivated and their LEDs will turn off. If the output
of a particular LED cannot be deactivated (due to panel programming
choices, for example), that LED will turn on steady.
3. If the LED is lit steady, the output will be deactivated, and the point-
active LED will turn off.
4. If the LED was flashing, the output will be turned off, the LED will turn
off, the next highest-priority LED within the same group will begin to
flash.
For example, in a system with three channels and four speakers, where channel
one has higher priority than channel two, which has higher priority than channel
three, the system would be set up with one ACM-24AT board, and DIP SW32
on the ACM-24AT would be set as follows:
•SW32-2 OFF
SW32-3 ON
•SW32-4 OFF
In this example, point mappings are as shown the “3 Switches per Group”
section of Table 4-3. If Switch 8 were pressed with no lit LEDs in the group, the
output of Channel 2 would be directed to speaker circuit 3, and the point-active
LED at switch P8 would flash.
Configuring Switch Groups
Annunciator switches can be set in groups from one-point up to eight-points. If
selecting 5-point or 7-point groups, note that there will be some unused
switches; any unused points should be programmed as monitor points.
Configure Speaker Control Mode with DIP switch SW32-2, SW32-3, and
SW32-4 according to the point assignments shown in Table 4-2.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Notifier ACM-16AT and is the answer not in the manual?

Notifier ACM-16AT Specifications

General IconGeneral
BrandNotifier
ModelACM-16AT
CategoryFire Alarms
LanguageEnglish

Summary

Section 1 Product Overview

1.1 General

Provides a general overview of ACS annunciators and their system integration.

1.1.1 Panel Compatibility

Lists fire alarm control panels compatible with ACS annunciators and their point capacities.

1.1.2 ACM-24AT, ACM-48A, AEM-24AT, and AEM-48A

Details capabilities and system compatibility for ACM/AEM-24AT/48A series annunciators.

1.1.3 ACM-16AT, ACM-32A, Expanders, and Variations

Describes ACM/AEM-16AT/32A series annunciators, expanders, and variations.

1.2 Related Documentation

Lists part numbers for related documentation and manuals for compatible equipment.

Section 2 Product Overview

2.1 ACM-24AT and AEM-24AT

Details the Annunciator Control Module (ACM-24AT) and its Expander (AEM-24AT).

2.2 ACM-48A and AEM-48A

Details the Annunciator Control Module (ACM-48A) and its Expander (AEM-48A).

2.3 ACM-16AT Series

Covers ACM-16AT series control modules and their variations.

2.4 ACM-32A Series

Covers ACM-32A series control modules and their variations.

2.5 Cabinet & Panel Hardware

Details surface-mount, flush-mount, and semi-flush-mount backboxes for annunciators.

Section 3 Design Considerations

3.1 Limits

Outlines limitations for EIA-485 circuits, number of annunciators, and power capacity.

3.2 Wire Runs

Explains the 2-wire EIA-485 serial interface for communication and power requirements.

3.3 EIA-485 Wiring Specifications

Provides specifications for EIA-485 circuit wiring, including cable type and tapping rules.

3.4 Receive/Transmit and Receive Only Configuration

Differentiates between Receive/Transmit and Receive Only annunciator operational modes.

3.5 Cabinet Mounting of Annunciators

Describes mounting requirements for ACS modules in various cabinets and dress panels.

3.6 Annunciator Power Requirements & Electrical Ratings

Details input voltage, data communication port specifications, and power requirements.

Section 4 Installation, Configuration, and Programming

4.1 Installation Checklist

A step-by-step checklist for installing ACS annunciators and expanders.

4.2 Connections and Switches

Illustrates connections and identifies switches for ACM-24AT/48A and ACM-16AT/32A series.

4.3 Mount the Cabinet or Backbox

Provides instructions for mounting cabinets and backboxes, including grounding.

4.4 Mount Annunciators and Expanders

Guides on mounting annunciators and expanders to dress plates and connecting them.

4.5 EIA-485 Circuit Connections

Shows EIA-485 circuit diagrams for connecting annunciators to the control panel.

4.6 Shielding the EIA-485 Circuit

Explains proper shielding techniques for EIA-485 circuits to prevent interference.

4.7 End of Line Resistor for EIA-485 Circuit

Details the installation or enabling of an end-of-line resistor for EIA-485 circuits.

4.8 Earth Ground

Specifies the connection points for earth ground on different annunciator models.

4.9 Main Power Supply Connections

Describes how to connect the main power supply to the ACS annunciators.

4.10 Labeling Annunciators & Expanders

Instructions for applying slide-in and adhesive labels for annunciators.

4.11 Connecting Annunciator Key Switch and Phone Jack

Guides on connecting optional key switches and phone jacks to annunciators.

4.12 Setting Address and DIP Switches: ACM-24AT, ACM-48A

Details setting address and DIP switches for ACM-24AT/ACM-48A models.

4.13 Setting Address and DIP Switches: ACM-16AT, ACM-32A

Details setting address and DIP switches for ACM-16AT/ACM-32A models.

4.14 Supervising Devices with ACM-16AT, ACM-32A

Explains how to use the trouble input for supervising external devices.

4.15 Programming the Control Panel and Annunciators

Covers programming the control panel and selecting LED colors for annunciators.

4.16 Testing the Annunciators

Outlines procedures for testing annunciator functions, LEDs, and colors.

Section 5 LED and Keypad-Switch Functions

5.1 ACM-24AT, ACM-48A, and Expanders

Describes LEDs and keypad switch functions for ACM/AEM-24AT/48A series.

5.2 ACM-16AT, ACM-32A, and Expanders

Describes LEDs and keypad switch functions for ACM/AEM-16AT/32A series.

APPENDIX L AFP-100 Systems

L.1 Capabilities

Outlines the capabilities of ACS annunciators with AFP-100 systems.

L.2 Connecting the EIA-485 Circuit

Details EIA-485 circuit connection to the AFP-100.

L.3 Providing Power to Annunciators

Explains how to provide power to annunciators from the AFP-100.

L.4 Configuring Annunciators for AFP-100

Details DIP switch settings for configuring annunciators with AFP-100.

APPENDIX M AFP-200 Systems

M.1 Capabilities

Outlines ACS annunciator capabilities with AFP-200 systems.

M.2 Connecting the EIA-485 Circuit

Details EIA-485 circuit connection to the AFP-200.

M.3 Providing Power to Annunciators

Explains how to provide power to annunciators from the AFP-200.

M.4 Configuring Annunciators for the AFP-200

Details DIP switch settings for configuring annunciators with AFP-200.

APPENDIX N AFP-300/AFP-400

N.1 Capabilities

Outlines ACS annunciator capabilities with AFP-300/AFP-400 systems.

N.2 Connecting the EIA-485 Circuit

Details EIA-485 circuit connection to the AFP-300/AFP-400.

N.3 Providing Power to Annunciators

Explains how to provide power to annunciators from the AFP-300/AFP-400.

N.4 Configuring Annunciators for the AFP-300/AFP-400

Details DIP switch settings for configuring annunciators with AFP-300/AFP-400.

N.5 System and Point Annunciation

Describes system and point mapping for AFP-300/AFP-400.

APPENDIX O AFC-600 Systems

0.1 Capabilities

Outlines ACS annunciator capabilities with AFC-600 systems.

O.2 Connecting the EIA-485 Circuit

Details EIA-485 circuit connection to the AFC-600.

O.3 Providing Power to Annunciators

Explains how to provide power to annunciators from the AFC-600.

0.4 Configuring Annunciators for the AFC-600

Details DIP switch settings for configuring annunciators with AFC-600.

0.5 System and Point Annunciation

Describes system and point mapping for AFC-600.

APPENDIX P AM2020/AFP1010 Systems

P.1 Capabilities

Outlines ACS annunciator capabilities with AM2020/AFP1010 systems.

P.2 Connecting the EIA-485 Circuit

Details EIA-485 circuit connection to the AM2020/AFP1010.

P.3 Providing Power to Annunciators

Explains how to provide power to annunciators from the AM2020/AFP1010.

P.4 Programming the AM2020/AFP1010 for Remote Annunciation

Details programming the AM2020/AFP1010 for remote annunciator functions.

P.5 Configuring Annunciators for AM2020/AFP1010

Details DIP switch settings for configuring annunciators with AM2020/AFP1010.

P.6 Configurations for Specific Applications

Covers specific application configurations like common annunciation and speaker/telephone modes.

P.7 ACS Program Mapping

Details the ACS program mapping for devices and functions.

APPENDIX Q NFS-640 Systems

Q.1 Capabilities

Outlines ACS annunciator capabilities with NFS-640 systems.

Q.2 Connecting the EIA-485 Circuit

Details EIA-485 circuit connection to the NFS-640.

Q.3 Providing Power to Annunciators

Explains how to provide power to annunciators from the NFS-640.

Q.4 Configuring Annunciators for the NFS-640

Details DIP switch settings for configuring annunciators with NFS-640.

Q.5 System and Point Annunciation

Describes system and point mapping for NFS-640.

APPENDIX R System 500 Systems: ACM-16AT and ACM-32A Only

R.1 Capabilities

Outlines ACS annunciator capabilities with System 500.

R.2 Connecting EIA-485 Circuit

Details EIA-485 circuit connection to the System 500.

R.3 Providing Power to Annunciators

Explains how to provide power to annunciators from the System 500.

R.4 Configuring the ACS for System 500

Details DIP switch settings for configuring ACS with System 500.

R.5 ACS Program Mapping

Details ACS program mapping for System 500.

APPENDIX s System 5000 Systems: ACM-16AT and ACM-32A Only

S.1 Capabilities

Outlines ACS annunciator capabilities with System 5000.

S.2 Connecting the EIA-485 Circuit

Details EIA-485 circuit connection to the System 5000.

S.3 Providing Power to Annunciators

Explains how to provide power to annunciators from the System 5000.

S.4 Installing Modules in the System

Describes the procedure for installing ACS modules within the System 5000.

S.5 Configuring the ACS for System 5000

Details DIP switch settings for configuring ACS with System 5000.

S.6 ACS Program Mapping

Details ACS program mapping for System 5000.

S.7 AIM-200 Point Annunciation

Describes point annunciation using the AIM-200 with System 5000.

APPENDIX T Combination Fire Alarm/Burglary Systems

APPENDIX U NCA Systems

U.1 Capabilities

Outlines ACS annunciator capabilities with NCA systems.

U.2 Connecting the EIA-485 Circuit

Details EIA-485 circuit connection to the NCA.

U.3 Providing Power to Annunciators

Explains how to provide power to annunciators from the NCA.

U.4 Programming the NCA for Remote Annunciation

Details programming the NCA for remote annunciator functions.

U.5 Configuring Annunciators for the NCA

Details DIP switch settings for configuring annunciators with the NCA.

APPENDIX V NFS-3030 Systems

V.1 Capabilities

Outlines ACS annunciator capabilities with NFS-3030 systems.

V.2 Connecting the EIA-485 Circuit

Details EIA-485 circuit connection to the NFS-3030.

V.3 Providing Power to Annunciators

Explains how to provide power to annunciators from the NFS-3030.

V.4 Programming the NFS-3030 for Remote Annunciation

Details programming the NFS-3030 for remote annunciator functions.

V.5 Configuring Annunciators for NFS-3030

Details DIP switch settings for configuring annunciators with NFS-3030.

V.6 Configurations for Specific Applications

Covers specific application configurations like common annunciation and speaker/telephone modes.

V.7 ACS Program Mapping

Details ACS program mapping for NFS-3030.

Limited Warranty