NFS2-3030 Operations Manual — P/N 52546:N1 06/20//2014 9
About This Manual General Information
1.3 About This Manual
The following graphics appear in the manual to indicate a caution, a warning, or a note.
1.4 Introduction to the Control Panel
The NFS2-3030 is an intelligent Fire Alarm Control Panel (FACP) with features suitable for most
applications. The CPU2-3030 comes with a front display/keypad option, which allows program-
ming and viewing options at the panel.
There are two basic configuration options for the NFS2-3030. It can be ordered with:
a front display/keypad, which allows programming and viewing options at the panel, or
no display keypad.
This manual gives instructions using the front display/keypad.
Displayless Mode
When there is no keypad/display at the NFS2-3030, the panel is controlled by remote annunciators.
VeriFire® programming is required. The displayless panel has four buttons on its circuit board that
are service-level switches for local operation should it become necessary. They are the only but-
tons, and are clearly marked with ACK for Acknowledge, SIGSIL for Signal Silence, SYSRST for
System Reset, and LAMP TEST. These buttons are mainly for installer use: the operator should uti-
lize a remote annunciator for these functions, if possible. The status indicator LEDs on the circuit
board are the same as on the display/keypad (refer to Section 1.5.1, “The Display/Keypad”, on page
11 of this manual).
Refer to VeriFire® Tools or the NCA-2 Manual for information on programming without the NFS2-
3030 display/keypad.
XP6-C Supervised Control Module Installation Document I56-1805
XP6-MA Six Zone Interface Module Installation Document I56-1806
XP6-R Six Relay Control Module Installation Document I56-1804
FSA-8000 Intelligent Aspiration Sensing Technology Document I56-3903
XPIQ Audio Transponder Manual 51013
SLC-IM Listing Document LS10026-051NF-E
SLC-IM Manual LS10026-000NF-E
SWIFT™ Network Manual LS10036-000NF-E
Table 1.1 Related Documents (3 of 3)
!
CAUTION:
INFORMATION ABOUT PROCEDURES THAT COULD CAUSE PROGRAMMING ERRORS,
RUNTIME ERRORS, OR EQUIPMENT DAMAGE.
!
WARNING:
INFORMATION ABOUT PROCEDURES THAT COULD CAUSE IRREVERSIBLE DAMAGE TO
THE CONTROL PANEL, IRREVERSIBLE LOSS OF PROGRAMMING DATA OR PERSONAL
INJURY.
NOTE: Information that highlights an important part of the preceding or subsequent text or
illustration.

Other manuals for Notifier NFS2-3030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Notifier NFS2-3030 and is the answer not in the manual?

Notifier NFS2-3030 Specifications

General IconGeneral
TypeIntelligent Fire Alarm Control Panel
Power Supply (6 amps total system power)6 amps total system power
SLC Loop Voltage24V DC
NAC Voltage24V DC
Operating Temperature0°C to 49°C (32°F to 120°F)
Humidity Range10% to 93% non-condensing
Network CapabilityYes, via NOTI-FIRE-NET
ProgrammingVia VeriFire Tools
Power Supply120V or 240V AC, 50/60 Hz
Battery BackupYes
Communication PortsRS-232, USB
SLC Loops1 or 2
NAC Outputs4
Operating Voltage24V DC nominal
Number of Signaling Line Circuits (SLC)2
SLC Loop Current0.5 A max per loop
Number of Notification Appliance Circuits (NAC)4
Total NAC Current6 amps
Number of Relays4
Relay Contact Rating2.0 A @ 30 VDC