88 NFS2-3030 Operations Manual — P/N 52546:N1 06/20//2014
Index
A
Abort 82
AC Fail Delay Timer
49
Setting report
71
ACCEPT soft key
18
Acknowledge
An Event
25
Block and point
25
Acknowledge soft keys
disabled local control
12
ACS Points Report
75
Active Fire Control Point
Panel indication
49
Active Non-fire Point
Panel indication
49
Active Points Report
73
Address formats
51
Alarm Verification timer
49
Alphanumeric keyboard, function of
12
Annunciator
Address format
51
Read Status
62
Arrow Keys
about
13
use of
18
Auto Silence timer
50
Setting report
71
B
BACK soft key 18
BATTERY LEVELS key, about
13
Block Acknowledge
25
Block acknowledge setting report
71
Broadcast time setting report
71
C
Canada Event Order 21
Canadian Applications
37
CAUTION
Information about the Caution notation
9
When a zone is disabled, any input or out-
put devices mapped…
48
CMM - 1/27/14 - Added the Log Wireless State
option to the Event Logging printout.
73
CO Alarm
How to respond
41
Panel indications
40
CO Pre-alarm
42
How to respond
42
Panel indications
42
Control Module
Read Status
5758
Co-operative Multi-Alarm Sensing display
21
Cross Zone
82
Cross Zone Programming illustration
83
Custom Action Message
20
Custom Action Messages report
73
D
DAA Speaker Ckt Address 52
DCC, see Display and Control Center
Delay Timer
82
Detector
Action/Status display
20
Address format
51
Aspiration Detector Read Status
56
Co-operative Multi-alarm Sensing
21
Heat Detector Read Status
54
Peaks display
21
Read Status
5255
values display
20
Verify Count display
21
Device Troubles
28
DISABLE/ENABLE key, about
13
Disabled Points
Panel indication
48
primary zone
48
Display and Control Center (DCC)
12, 25
Displayless Mode
9
service-level switches, ACK, SIGSIL,
SYSRST, LAMP
9
Drill
disabled local control
12
DRILL HOLD 2 SEC. fixed function key
12
E
Enter key, about 13
Esc key, about
13
Event
Acknowledging
25
CO Alarm
40
Definition of
24
Fire Alarm
25
History report
66
History screen
66
Mass Notification
43
Off-normal
24
Event Logging
Report listing
73
Event Ordering
21
Event ordering setting report
71
Event reporting format
14
point events
14

Other manuals for Notifier NFS2-3030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Notifier NFS2-3030 and is the answer not in the manual?

Notifier NFS2-3030 Specifications

General IconGeneral
TypeIntelligent Fire Alarm Control Panel
Power Supply (6 amps total system power)6 amps total system power
SLC Loop Voltage24V DC
NAC Voltage24V DC
Operating Temperature0°C to 49°C (32°F to 120°F)
Humidity Range10% to 93% non-condensing
Network CapabilityYes, via NOTI-FIRE-NET
ProgrammingVia VeriFire Tools
Power Supply120V or 240V AC, 50/60 Hz
Battery BackupYes
Communication PortsRS-232, USB
SLC Loops1 or 2
NAC Outputs4
Operating Voltage24V DC nominal
Number of Signaling Line Circuits (SLC)2
SLC Loop Current0.5 A max per loop
Number of Notification Appliance Circuits (NAC)4
Total NAC Current6 amps
Number of Relays4
Relay Contact Rating2.0 A @ 30 VDC