NFS2-3030 Operations Manual — P/N 52546:N1 06/20//2014 89
Index F–O
system events 16
F
F1 and F2 keys, about 13
Fields, adding/modifying
18
Fire Alarm
How to respond
26
Panel indications
25
FIRE ALARM SCROLL/DISPLAY fixed func-
tion key
12
Firmware version numbers, to view
13
Fixed Function Keys, functions of
12
G
General Zone
Address format
51
Read Status
59
General Zones Installed Points Report
75
H
History Information, viewing & printing 6568
All events
65
Event History report
66
Event History screen
66
Point Range
67
Range
68
Time & Date Range
67
I
Installed Points Report 74
Interval selection, all events
67
L
label 15, 17
LAMP TEST key, about
13
LCD Display report
72
LED Indicators
13
Local Control option
12
Logic Zone
Address format
51
Read Status
59
Logic Zones Installed Points Report
75
M
Main Menu 18
Event Counts display
18
History Select
23
More Information
19
Multiple Event List
21
Printer Functions
23
Program/Alter Status
23
Read Status
23
Manual Release
82
Mass Notification
MN Alarm Indication
43
MN Supervisory Indication
44
MN Trouble Indication
46
Point Trouble Indication
46
Supervisory Point Indication
44
Message Formats
Point Events
14
System Events
16
System Normal
14
Message Formats, about
1416
MN Alarm
How to respond
44
MN Supervisory
Panel indication
44
MN Trouble
How to respond
47
Module
Address format
51
See also Control Module
57
See also Monitor Module
56
Monitor Module
Read Status
56
Multiple Event List
21
N
Navigating menu and programming screens 18
Network parameters report
71
NEXT SELECTION/PREVIOUS SELECTION
key, about
13
Note
For a printed list of history information, re-
fer to…
73
If a monitor module programmed with a
Waterflow type code…
25
If an unacknowledged event occurs while
the Multiple Event list displays…
22
If Local Control is disabled…
25
If the panel is programmed for Receive
Mode…
25
Information about Notes
9
Key functions are as described below un-
less…
12
Report formats are shown below as printed
by an 80-column printer…
69
The first four lines of the display may indi-
cate an alarm for a point unrelat-
ed…
52
O
Off-normal events 24
OTHER EVENT SCROLL/DISPLAY fixed
function key
12

Other manuals for Notifier NFS2-3030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Notifier NFS2-3030 and is the answer not in the manual?

Notifier NFS2-3030 Specifications

General IconGeneral
TypeIntelligent Fire Alarm Control Panel
Power Supply (6 amps total system power)6 amps total system power
SLC Loop Voltage24V DC
NAC Voltage24V DC
Operating Temperature0°C to 49°C (32°F to 120°F)
Humidity Range10% to 93% non-condensing
Network CapabilityYes, via NOTI-FIRE-NET
ProgrammingVia VeriFire Tools
Power Supply120V or 240V AC, 50/60 Hz
Battery BackupYes
Communication PortsRS-232, USB
SLC Loops1 or 2
NAC Outputs4
Operating Voltage24V DC nominal
Number of Signaling Line Circuits (SLC)2
SLC Loop Current0.5 A max per loop
Number of Notification Appliance Circuits (NAC)4
Total NAC Current6 amps
Number of Relays4
Relay Contact Rating2.0 A @ 30 VDC