Do you have a question about the NOVA BIOMEDICAL Stat Profile PRIME and is the answer not in the manual?
Type | Blood Gas Analyzer |
---|---|
Display | Color touchscreen |
Measurement Parameters | pH, PCO2, PO2, Na+, K+, Cl-, Glucose, Lactate, Hct |
Sample Type | Whole blood, plasma |
Sample Volume | 100 microliters |
Analysis Time | Approximately 60 seconds |
Calibration | Automatic |
Connectivity | USB, Ethernet |
Power Requirements | 100-240 VAC, 50/60 Hz |
Operating Temperature | 15-30°C (59-86°F) |
Humidity Range | 10-90% non-condensing |
Information on how to order the Stat Profile® PRIME™ CCS Instructions for Use Manual.
Contact details for the authorized representative in the European Community.
Information on registered trademarks of Nova Biomedical Corporation.
Copyright notice for the Stat Profile® PRIME™ CCS Instructions for Use Manual.
Explains the manual's purpose, conventions (NOTE, CAUTION, WARNING).
General safety information and procedures for operating the analyzer.
Outlines essential safety precautions for operating the analyzer.
Safety guidelines related to the analyzer's electrical components and power supply.
Compliance statement for Federal Communications Commission rules.
Compliance statement for Industry Canada licence-exempt RSS standards.
Precautions for handling chemical and biological materials with the analyzer.
Covers installation requirements and procedures for the analyzer.
Details environmental, electrical, and humidity requirements for the analyzer.
Describes the analyzer's purpose, measured parameters, and clinical applications.
Information on sample types, minimum volume, and handling requirements.
Step-by-step guide for powering on the analyzer and its initialization process.
Description of the analyzer's main operational screen and its components.
Explains the analyzer's automated calibration process and its importance.
Detailed steps for analyzing patient samples, including login and sample preparation.
Instructions on how to use the Luer station for sample aspiration.
Procedure for analyzing samples from standard blood collection tubes.
Procedure for analyzing samples from capillary tubes.
Explanation of how sample results are displayed, including bar graphs.
Procedures for running internal and external quality control and proficiency samples.
Guidance on performing preventive maintenance and scheduled component replacements.
Detailed steps for replacing the calibrator and control cartridges.
Instructions for replacing the sensor card in the analyzer.
Steps for replacing the pump tubing.
Procedure for replacing the analyzer probe or air detector.
Instructions for replacing the reference sensor.
Guide for replacing the paper roll in the analyzer's printer.
Procedure for replacing the safety sample port.
General methods and steps to diagnose and resolve analyzer errors.
How to access and interpret the analyzer's error logs.
Procedure to verify fluid flow through the system and identify clogs or leaks.
Technical specifications for the Stat Profile Prime CCS Analyzer, including measurement ranges.
Details on how substances may interfere with test results.
Results from studies comparing the analyzer's performance to other models.
Data from method comparison studies using syringe samples.
Data on the analyzer's precision and repeatability.
Performance data related to precision across multiple runs.
Information about the calibrator cartridge, including traceability.
Provides reference values for various analytes measured by the analyzer.
List of supplies and parts available for order from Nova Biomedical.
Details the warranty terms and conditions for the analyzer.
Describes how key parameters like electrolytes and gases are measured.
Explains the equations used to calculate derived parameters from measured values.