Instructions for the user
1.4.4 Shut-down due to low water pressure
Fault code E04 is displayed on the LCD display in the event of shut-down triggered by the water pressure switch.
Fill the system by working on ller cock (A) (see Fig. 2 Filler cock).
Water pressure must be 1÷1.3 bars while the boiler is cold.
In order to restore water pressure, proceed as follows:
Turn the ller cock anticlockwise to allow water to enter the boiler;
Keep the ller cock open until the pressure gauge shows a value of 1÷1.3 bar;
Turn cock clockwise to close it.
Should boiler shuts down frequently occur it means there is boiler malfunction in progress. Contact qualied personnel or an authorised
service centre for maintenance.
DANGER
Make sure you close ller cock (A) carefully after lling procedure is completed.
If you do not, when the pressure increases, the safety valve may activate and discharge water.
Fig. 2 Filler cock
1.4.5 Alarm due to temperature probe malfunction
The following fault codes are shown on the display in the event of burner shut-down due to a temperature probe fault:
E05 for the CH probe: in this case the boiler does not work.
E06 for the DHW probe; in this case, the boiler functions in central heating mode only, and the DHW function is disabled.
WARNING
In any case, contact a service centre or qualied personnel for maintenance.