Maintenance
5. Maintenance
WARNING
Any maintenance (and repair) work must only be carried out by qualied personnel.
The user is strongly advised to have the product serviced and repaired by a service centre or qualied personnel.
Appropriate boiler maintenance ensures ecient operation, environment preservation, and safety for people, animals and objects.
The boiler must be serviced at least once every year.
WARNING
Disconnect electric power supply before starting any maintenance procedure, involving replacement of components and/or
cleaning inside parts of boiler.
5.1 Maintenance schedule
Maintenance operations include check and cleaning procedures. In particular:
Inspections and checks
Check general integrity of the boiler.
Check boiler and network gas supply for leakage.
Check gas supply pressure to boiler.
Check minimum and maximum gas pressures to boiler nozzles.
Check boiler ignition sequence.
Check the condition and seal integrity of the ue gas venting ducts.
Check operation of safety thermostat installed on the draught excluder.
Check the condition of the draught excluder.
Check that there is no ue gas return into the room and that the ue gases are vented correctly.
Check integrity of safety devices of the boiler in general.
Check for water leaks and oxidised areas on the boilers couplings.
Check eciency of the system safety valve.
Check expansion vessel lling pressure.
Check water pressure switch eciency.
The following cleaning is to be done
Clean the general interior of the boiler.
Clean the gas nozzles.
Clean the draught excluder.
Clean the ventilation grille in the room in which the boiler is installed.
Clean the heat exchanger.
When checking the boiler for the very rst time, also verify:
Boiler room suitability.
The ventilation apertures in the room in which the boiler is installed.
Diameter and length of ue gas system ducts.
Boiler installation in accordance to this “Installation use and maintenance manual instructions.