32
Instructions for the installer
Parameter Description
Congurable value
range
Default values Notes
P30 Display of external temperature n.a. n.a.
only with external probe
connected
P31 Display of ow temperature n.a. n.a. n.a.
P32
Nominal calculated ow
temperature
n.a. n.a.
only with external probe
connected
P42
Displaying of plate DHW
temperature
n.a. n.a.
P50 Display of boiler type C; B
According to the
model
C = forced draught; B = natural
draught
P51
Display of most recent boiler
shut-down
n.a. Fault code n.a.
P52
Display of penultimate boiler
shut-down
n.a. Fault code n.a.
P53
Display of third last boiler shut-
down
n.a. Fault code n.a.
P54
Display of fourth last boiler shut-
down
n.a. Fault code n.a.
P55
Display of fth last boiler shut-
down
n.a. Fault code n.a.
P56 Number of faults since last reset n.a. n.a. n.a.
P57 Board use month displaying n.a. n.a. n.a.
P95
Display of reset shut-down and
fault
0 ÷ 1 n.a.
0 = OFF; 1 = shut-downs and
faults reset
Tab. 6 Limits to be set for TSP parameters and default values in relation to boiler type (TSP0) - II