Technical features and dimensions
2.1.3 Operating features
Electronic ame modulation in CH mode, with timed rising ramp.
Electronic ame modulation in DHW mode.
Flow freeze protection function: ON 5°C; OFF 30°C or after 15 minutes of operation if CH temperature > 5 °C.
DHW freeze protection function (CTFS): ON 5°C; OFF 10 °C or after 15 minutes of operation if DHW temperature > 5 °C.
Timer-controlled ue cleaning function: 15 minutes.
CH Maximum heat input parameter adjustment.
Ignition heat input adjustment parameter.
Ignition ame propagation function.
CH thermostat timer: 240 seconds (adjustable).
Heating pump post-circulation function in CH, freeze protection and ue cleaning modes: 30 seconds (adjustable).
DHW post-circulation function: 30 seconds (adjustable).
Post-circulation function for heating temperature > 78 °C: 30 seconds.
Circulation pump and deviating valve anti shut-down function: 30 seconds of operation after 24 hours of inactivity.
Ready for connection to an (optional) ambient thermostat.
Ready for operation with an external probe (optional, supplied by the manufacturer).
Ready for operation with an OpenTherm remote control (optional, supplied by the manufacturer).
Anti-water hammer function: can be set from 0 to 3 seconds.
DHW function priority.