Instructions for the installer
DANGER
The boiler is equipped with a safety device for ue gas exhaustion check.
It is strictly forbidden to tamper with and/or prevent operation of such safety device.
Should an air/ue gas system malfunction occur, the device will shut-down the boiler by interrupting the gas supply to the boiler
and the LCD will display the E03 code.
In this case it is necessary to have safety device, boiler and the air intake/ue gas venting ducts promptly checked by a service
centre or a qualied service engineer.
In case of repeated stops, it is necessary to have safety device, boiler and the air intake/ue gas venting ducts checked by a service
centre or a qualied service engineer.
After each operation on the safety device or the air suction/ue gas exhaust system, it is necessary to perform a functional test of
the boiler.
In case it is necessary to replace the safety device use only original spare parts supplied by the Manufacturer.
The actual waiting time for the automatic reset of the combustion gas exhaust control device is equal to 10 minutes. To reset the
device before this time it is necessary to press "Reset".
DANGER
Damage and/or injury caused by incorrect installation and/or incorrect use and/or unauthorized changes to the boiler and/or non-
observance of the manufacturer’s instructions and/or of the relative standards/laws in force in the country of installation, shall
release the manufacturer from any and all liability.