10Maintenance
10.1Tasks to be performed before starting maintenance
NOTICE
NOTICE
For your safety, we recommend that the door system be checked before initial use
and as needed – at least once a year – in accordance with the check list in the
Inspection chapter. The check can be carried out by a person with the
corresponding qualification certificate or by a specialist company.
First carry out the following steps before performing maintenance activities on the
door:
1. Disconnect from the mains.
2. Secure against inadvertent switch-on.
3. Verify de-energised state.
4. Please note that works on the electrical system only be performed by skilled
electricians or instructed persons working under the direction and supervision of
a skilled electrician in accordance with the electrotechnical rules and directives
may.
10.2Maintenance release (variant-specific)
The variants with the quick chain and emergency crank handle are equipped with an
optional maintenance unlocking function which mechanically disconnects the drive
from the door and allows the door to be checked for ease of motion.
This function may only be operated when the drive is at a standstill. The drive must
also be disconnected from the power supply.
1. Loosen the screw and remove the cover(1).
2
1
2. Turn the red lever(2) in clockwise direction while disconnecting the drive from
the door.
ð The door can now be moved by hand and the door movement can be checked.
10.3Inspection
When being commissioned, power-operated doors must be inspected and maintained
by correspondingly qualified persons (persons with suitable qualifications, based on
knowledge and experience) and in compliance with intervals specified by the manu-
facturer in the maintenance instructions and, if necessary, also in accordance with
any special national regulations (e.g. ASRA1.7 "Technical Rules for Workplace
Safety - doors and gates"). All maintenance and inspection tasks must be docu-
mented in the inspection logbook provided. It must be kept safe by the operating
company, together with the documentation of the door system, throughout the entire
service life and must be handed over to the operating company in a duly completed
fashion, at the latest on the date of commissioning by the technician (we also re-
commend this for manually operated doors). The specifications laid down in the doc-
umentation of the door system (assembly, operating and maintenance instructions,
etc.) must be absolutely observed in any case.
The manufacturer's warranty expires immediately if the inspection / maintenance
has not been carried out properly!
Any changes that are made to the door system (if permitted at all) must also be doc-
umented.
22|Novoferm

Table of Contents