Regular Maintenance
After use, empty waste water tank
using emptying hose and ush out
with clean water.
Next remove oor tool vacuum hose
and ush out with clean water.
Next empty clean water tank, using
emptying hose and again ush out
with clean water.
A
B
C
ALWAYS ENSURE THAT THE MACHINE IS SWITCHED OFF PRIOR TO ANY
MAINTENANCE USING THE MASTER CONTROL ON/OFF KEY.
REMOVE THE KEY PRIOR TO ANY MAINTENANCE OPERATION.
!!
A
B
C
Whilst pressing in the top tank hood
toggles, remove the hood. (Fig.1)
The hood also has a sealing-rubber which
should be examined at every clean-down.
Rinse using clean water, avoiding the
vac lter.
Remove the lter tted into the separator
and ush with clean-water (Fig.2)
IMPORTANT
Remove vac lter and clean if required
(keep dry).
Never use the machine without the
recommended lter as it may cause
damage to the machine.
Remove debris basket lter and rinse
using clean water, and ret. (Fig.3)
IMPORTANT If the debris basket is
allowed to become clogged, vacuum
performance can deteriorate.
Located under the left hand side is a clean water lter, make sure
the clean water tank is empty before removing this lter.
Note: To make access easier, raise the brush deck.