Battery Care
UNDER NORMAL DAILY USAGE:
Re-charge the machine FULLY after each use regardless of machine operation time.
Do not leave the machine in a discharged state.
To ensure your machine remains at its maximum eciency
and prolong your battery life, please follow the simple steps below:
!!
Signal (LED) Meaning
Red LED on First Phase (constant current Mode)
Yellow LED on Second Phase (Constant Voltage Mode)
Green LED on Third Phase (Constant Voltage Mode) Charge Complete
Red LED ashing
followed by Pause
Charging System Error
Unsuitable battery or charging malfunction safety timer exceeded
Internal short circuit, disconnect from power supply, switch power supply,
OFF then ON, to restart the charging cycle
Yellow LED ashing Battery not connected
Under abnormal use;
i.e. leaving the machine without charging for a period of time, we advise that you follow these steps:
If the machine will be standing unused for a period of 30 days or more, then batteries
must be fully charged and battery fuses removed using the maxi fuse-puller provided,
prior to this period.
Batteries should be re-charged every three months.
Charge fully the day before you start using the machine again.
Charging Light Sequence
Re-charge the machine fully after its last use. Do not leave the machine in a discharged state.