Step 2. Congure a serial terminal program (for example, HyperTerminal, minicom, or Tera
Term) on your host PC with the settings described in the table below. Once you perform
that, you should get the CLI prompt of the system.
Serial Terminal Program Conguration
Parameter Setting
Baud Rate 115200
Data bits 8
Stop bits 1
Parity None
Flow Control None
Step 3. Login as admin and use admin as password. On the rst login, the NVIDIA Onyx
(MLNX-OS) conguration wizard will start.
Step 4. To congure network attributes and other initial parameters to the system, follow
the conguration wizard as shown in the Conguration Wizard Session table below.
Conguration Wizard Session
Wizard Session Display Comments
NVIDIA conguration wizard
Do you want to use the wizard
for initial conguration? yes
You must perform this conguration the rst time you
operate the system or after resetting the system. Type
‘y’ and then press <Enter>.
Step 1: Hostname? [switch-1]
If you wish to accept the default hostname, press
<Enter>. Otherwise, type a dierent hostname and
press <Enter>.
Consol