5. Maintenance Menu
When the [CANCEL] key is pressed while test is in progress (while the [ON
LINE] lamp is lighting), the screen returns to the state of step 2.
<<During execution of DENS ADJ RESULT>>
T
he
same as the key operations of step 2. During execution of DENS ADJ
EXECUTE.
<<During execution of DENS ADJ PAR - SET>>
Setup of the density correction parameter is display
ed.
<<During execution of AUTO CALIBRATION>>
The automatic setting of the density sensor sensitivity correction value is
executed. (The [ON LINE] lamp flashes.)
When the test is complete, the test result (OK or error name) is displayed in the
upper row of the display area, and ****RESULT is displayed in the lower row of
the display area
OK
DENS ADJ RESULT
When the [MENU+] key is pressed, the test results are displayed by
incrementing them.
Whe
n the [MENU-] key is pressed, the test results are displayed by
decrementing them.
Pressing the [BACK] ke
y returns the screen to the state of step 2.
When the [CANCEL] key is pressed while test is in progress (while the [ON
LINE] lamp is lighting), the screen returns to the state of step 2.
Remarks The follo
wing message is displayed during initialization, when the cover
is opened and during alarm.
NG
DENS ADJ RESULT
4. Repeat step 3 as required.
5. Pressing the [BACK] key terminates the test. (Returns to the status of step 1.)
Density correction test items
Display Details
DENS ADJ EXECUTE Executing the density correction
DENS ADJ PAR-SET Setting the control values with respect to the
automatic density correction
DENS ADJ RESULT Referring to result of the density correction
AUTO CALIBRATION Automatic setting of the density sensor sensitivity
correction value