Page #32 background imageLoading...
Page #32 background image
42089201TH Rev.4 32 /
Oki Data CONFIDENTIAL
2.2.3 Head Gap Adjusting (See Figure 2-5.)
The head gap adjusting lever moves back and forth to tilt the carriage frame, altering the gap
between the printhead and the platen.
The adjusting screw, which is connected to the adjusting gear rotates when the adjusting lever
is moved creating a fine gap adjustment. If the adjusting gear is pushed down, the adjusting
screw can be turned with a screw driver to change the coarse gap adjustment.
When the adjusting lever is set to range ~ the contact which is attached to the under side
of the carriage cover will connect with the contact of the space motor PC board. The printer
will reduce the printing speed automatically to ensure that adequate printing pressure is maintained
for multipart paper.
And, the adjusting cam adjusts the headgap toward left and right side in accordance with the
guide rail up and down as a position of the left end of it.

Table of Contents

Other manuals for Oki MICROLINE 320 Turbo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oki MICROLINE 320 Turbo and is the answer not in the manual?

Oki MICROLINE 320 Turbo Specifications

General IconGeneral
ColorNo
Built-in barcodesCode 39
Maximum resolution288 x 144 DPI
Maximum number of copies6 copies
Media thickness0.36 - 0.43 mm
Dimensions (WxDxH)399 x 355 x 117 mm
Networking featuresOkiLAN 6120e 10/100 Base-T
Connectivity technologyWired
Compatible operating systemsWindows Vista, XP, 2000/ME, 98 & NT 40; UNIX, MS-DOS, Novell
Page description languagesEpson FX
Sound pressure level (printing)52 dB
Mean time between failures (MTBF)10000 h
Power consumption (typical)100 W
Operating temperature (T-T)5 - 40 °C
Operating relative humidity (H-H)20 - 80 %