EasyManua.ls Logo

Oki Microline 3321

Oki Microline 3321
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42089201TH Rev.4 97 /
Oki Data CONFIDENTIAL
ALARM
CATEGORY
ALARM
LED DISPLAY
ALARM
10
12
15
17 20 PROP HSD UTL
NLQ
REMARKS
TROUBLESHOOTING
SPACING
ALARM
Spacing alarm
Print Head
homing alarm
Print Head
A/D alarm
Space IPT is not occurred
within in specified timing.
: LED Blink (200ms ON, 200ms OFF)
: LED Lights up
PRINT
HEAD
ALARM
Print Head Gap
A/D alarm
Replace space motor.
Replace P.H. cable.
Replace Control/
Power Supply Board
Check the mechanisms if
load is too much.
Check the P.H. connection.
Replace Print Head.
Replace P.H. cable.
Replace Control/Power
Supply Board
Print head does not reach
to the home position.
Thermister is open, short
with 0V or short with +5V.
Print Head Gap Signal open
Replace P.H. cable.
Replace Space Motor Assy.
Replace Control/Power
Supply Board
Table 6.3 (2/2)

Table of Contents

Other manuals for Oki Microline 3321

Related product manuals