42089201TH Rev.4 97 /
Oki Data CONFIDENTIAL
ALARM
CATEGORY
ALARM
LED DISPLAY
ALARM
10
12
15
17 20 PROP HSD UTL
NLQ
REMARKS
TROUBLESHOOTING
SPACING
ALARM
Spacing alarm
Print Head
homing alarm
Print Head
A/D alarm
Space IPT is not occurred
within in specified timing.
: LED Blink (200ms ON, 200ms OFF)
: LED Lights up
PRINT
HEAD
ALARM
Print Head Gap
A/D alarm
Replace space motor.
Replace P.H. cable.
Replace Control/
Power Supply Board
Check the mechanisms if
load is too much.
Check the P.H. connection.
Replace Print Head.
Replace P.H. cable.
Replace Control/Power
Supply Board
Print head does not reach
to the home position.
Thermister is open, short
with 0V or short with +5V.
Print Head Gap Signal open
Replace P.H. cable.
Replace Space Motor Assy.
Replace Control/Power
Supply Board
Table 6.3 (2/2)