EasyManua.ls Logo

Olimpia splendid MAESTRO SMART 9HP - External Coil Temperature Alarm

Olimpia splendid MAESTRO SMART 9HP
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAESTRO SMART 25
7.12.5 External coil temperature alarm
Is the external heat
exchanger temperature greater
than 70°C(158°F)?
Are the air intake/outlet
tubes free of
obstructions?
Does the external fan
turn correctly?
Is air recirculated
through the
intake/outlet tubes, or
are the grilles not
original parts?
Does the condensate
disposal system work
correctly?
Is the external
coil clean?
Clean the Coil
Replace worn components
Replace air tubes/grilles following
instructions in the manual
Verify whether operating
temperature is beyond the
stated limits
Check for mechanical blockage
and verify board in/out voltage
External exchanger temperature
too high
Check:
-
Thermoactuator
-
Pump
-
Check valve
-
Distributor
-
Floats
Clear obstruction