5
IPLEX NX
· Do not subject the LCD monitor to strong impact, strong pressure or
to scratching by a hard or pointed object.
Otherwise, the LCD monitor may be cracked or scratched, or the
damaged monitor may cause personal injury.
· When tilting the handle, be careful not to pinch your hands or any objects.
· Use SDHC card and microSDHC card recommended by Olympus to
record images.
This instrument comes with an SDHC card.
· Do not remove the battery or the AC adapter during operation.
Otherwise, the recorded data may be damaged.
· Do not remove the SDHC card or the USB flash drive while recording
or replaying the image.
Otherwise, the recorded data or the image recording media may be
damaged or lost.
· Do not repeat inserting or removing the SDHC card or the USB flash
drive continuously.
Otherwise, the recorded data or the image recording media may be
damaged or the SDHC card may not work properly.
· Be careful for followings when using the extendable handle of the
carrying case.
- Be careful you do not catch your hand when storing the handle inside
the carrying case.
- Do not attempt to lift the carrying case by holding the extendable
handle.
· Do not store the instrument in the following locations.
- Environments exposed to high temperature, high humidity and large
amounts of dust or particulate
- Locations exposed to direct sunlight or radiation
- Locations exposed to gas that includes halide
*1
Otherwise, the instrument may be damaged.
*1 The performance of some electrical parts may deteriorate due to the
halide in insecticides, pesticides and gaseous extinguishing agents, etc.
· Do not continue to use the instrument when it is wet with
condensation.
In case of a sudden temperature change, such as entering a warm room
from cold outside, condensation may be caused inside the instrument. Using
the instrument while it is wet with condensation may cause malfunction.
If condensation occurs, leave the instrument in the environment where it will
be used and allow the condensation to dry before using it.
· Do not insert the insertion tube into the inspection object which is in
an environment that exceeds the operating temperature range.
The continued use may damage or deteriorate the performance of the instrument.
· Do not use the instrument if the contaminants are attached to the
outer surface of the instrument.
The instrument may be damaged or the performance may be deteriorated.
· Do not cover the main unit with a plastic bag or other objects.
The inside of the instrument may not be cooled down sufficiently, which
may damage the instrument.
CAUTION
NOTE

Table of Contents