DP20 Economical Multisignal meter Instruction Manual
1.31 Precauons on installaon
1.32 Factory conguraon
Range 600 Vac
Scaling and decimal point 0/600 Vac = 0/600
Alarms 1
Type alarm as maximum
Setpoint 1000
Hysteresis 0 counts
Alarm 2
Type alarm as maximum
Setpoint 1000
Hysteresis 0 counts
External control o
Fast access all o
Tools
Opon.1 o (retains last conguraon value)
Step 1
Average 0
Oset reading 0
Second scaling 0/600
‘Eco’ mode o
Temperature resoluon
Degrees ºC
Alpha 385
cJc on
AC deadband 20
Brightness 3
Password o
Opon 1 conguraon
Opon analog output 0/100.0=4/20 mA
Opon serial Modbus RTU 9600 bps, address 1, format 8n1
Jumpers ‘S’ selected for 600 Vac
Jumper ‘T’ selected for ‘EK’ external control funcon
According to direcve 2012/19/EU, electronic
equipment must be recycled in a selecve and
controlled way at the end of its useful life.
This instrument has been designed and veried conforming to the 61010-1 CE Security
Regulaon, for industrial applicaons. Installaon of this instrument must be performed
by qualied personnel only. This manual contains the appropriate informaon for the
installaon. Using the instrument in ways not specied by the manufacturer may lead to a
reducon of the specied protecon level. Disconnect the instrument from power before
starng any maintenance and / or installaon acon.
The instrument does not have a general switch and will start operaon as soon as power is
connected. The instrument does not have protecon fuse, the fuse must be added during
installaon.
The instrument is designed to be panel mounted. An appropriate venlaon of the
instrument must be assured. Do not expose the instrument to excess of humidity.
Maintain clean by using a humid rag and do NOT use abrasive products such as alcohols,
solvents, etc. General recommendaons for electrical installaons apply, and for proper
funconality we recommend : if possible, install the instrument far from electrical noise
or magnec eld generators such as power relays, electrical motors, speed variators, ... If
possible, do not install along the same conduits power cables (power, motor controllers,
electrovalves, ...) together with signal and/or control cables. Before proceeding to
the power connecon, verify that the voltage level available matches the power levels
indicated in the label on the instrument. In case of re, disconnect the instrument from
the power line, re alarm according to local rules, disconnect the air condioning, aack
re with carbonic snow, never with water.
Risk of electrical shock. Instrument terminals can be connected
to dangerous voltage.
Instrument protected with double isolaon. No earth connecon
required.
Instrument conforms to CE rules and regulaons.
Note: The AC powered units cannot be shipped to Canada.

Other manuals for Omega DP20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omega DP20 and is the answer not in the manual?

Omega DP20 Specifications

General IconGeneral
BrandOmega
ModelDP20
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals