Sensor: Digital 4-wire (DB-9)
Supported Protocols:
TCP/IP, UDP/IP, ARP, ICMP, DHCP, DNS,
HTTP, and Telnet
LED Indicators: Network Activity, Network
Link, Diagnostics/Status
LCD Display: 16 digits, 6mm (0.23”)
Processor: Enhanced 8051, 22 MHz
Memory: 512 Kbytes Flash, 16 Kbytes SRAM
Memory Data Flash Card: 2 Mbytes or
2 months of data storage at 10 second
logging intervals, or 1 year at 1 minute
logging intervals. Atmel# AT45DCB002
Optional Flash Cards:
4 Mbyte (2 years at 1 minute intervals)
8 Mbyte (4 years at 1 minute intervals)
Relay Outputs: Two relays 1.5A @ 30Vdc
Management: Device configuration and
monitoring through embedded WEB server
Embedded WEB Server: Serves WEB
pages containing real-time data and live
updated charts within definable time
intervals.
POWER
Power Input: 9 to 12 Vdc
Consumption: 2.5 W max.
Safety Qualified ac Power Adapter
Nominal Output: 9 Vdc @ 0.5 A
Input: 100 to 240 Vac, 50/60Hz
Battery: 9 Vdc, alkaline
approximately 650 mA hours
ENVIRONMENTAL
Operating Temperature:
0 to 70°C (32 to 158°F)
Storage Temperature:
-40 to 80°C (-40 to 176°F)
PACKAGING
Material: Metal case with wall mount
bracket
iServer Housing Dimensions:
36.6H x 62W x 90D mm
(1.44 x 2.93 x 3.56 in)
Weight: 298 g (0.8 lbs.)
GENERAL
Agency Approvals: FCC-B, C/UL, CE
Software: packages available are--
iConnect, iLog, iFlash, and Mail Notifier;
compatible with all Windows operating systems.
41
PART 5 SPECIFICATIONS
SENSOR SPECIFICATIONS
Relative Humidity (RH)
Accuracy/Range: ±2% for 10 to 90%
±3% for 0 to 10% and 90 to 100%
Hysteresis: ±1% RH
Non-linearity: ±3%
Response Time: 4 seconds
(63% slowly moving air)
Repeatability: ±0.1%
Resolution: 0.03%, 12bit
NOTE: Reconditioning of the probe may be
necessary if the probe is stored for a period
of time in a harsh environment (temperatures
below 0°C or above 70°C or exposure to
chemical vapors). To recondition the probe:
heat probe for 24 hours @ 80 to 90°C
@ <5% RH, followed by rehydration for
48 hours @ 20 to 30°C @ > 74% RH.
Temperature (T)
Accuracy/Range*:
Wand Probe:
±0.5°C (±1°F) 0°C to 70°C (32°F to 158°F)
Industrial Probe:
±0.5°C (±1°F) for 0 to 80°C (32 to 176°F).
±1°C (±2°F) for -40 to 0°C and 80 to 124°C
(-40 to 32°F and 176 to 255°F)
*Note: extended temperature range is for
Industrial Probe only, the iServer’s operating
temperature is 0 to 70°C
Response Time: 5 seconds
(63% slowly moving air)
Repeatability: ±0.1°C
Resolution: 0.01°C, 14 bit
PROBE SPECIFICATIONS
Wand Probe: 198 mm long x 19 mm
diameter (7.8" x 0.75")
Cable with DB9 connector: 152 mm long (6")
Cable operating temperature:
0 to 8C (32 to 176°F)
Industrial Probe: 137mm or 51mm long x
16mm diameter (5" or 2" x 0.63")
Cable with DB9 connector: 3m or 0.9m long
(10’ or 3’)
Cable operating temperature:
-40 to 124°C (-40 to 257°F)
iSERVER SPECIFICATIONS
Interfaces
Ethernet: 10Base-T (RJ45)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omega I.Server MicroServer I.THX-M and is the answer not in the manual?

Omega I.Server MicroServer I.THX-M Specifications

General IconGeneral
BrandOmega
ModelI.Server MicroServer I.THX-M
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals