The REC-12 has
12
programmable features for maximum system cus-
tomization. The following pages describe each feature and its available options.
Feature
#1
Doors lock
90
seconds
after the ignition is turned OFF
Default setting:
OFF
(press UNLOCK)
Option:
ON
(press LOCK)
This feature will automatically lock the doors 90 seconds after the ignition key
is
turned off.
Feature
#2
Doors relock
90
seconds after remotely
unlocking
Default setting:
OFF
(press UNLOCK)
Option:
ON
(press LOCK)
This feature will automatically lock the doors 90 seconds after the transmitter is used to unlock the
doors.
Feature #3
Ignition activated
doorlock
control
Default setting:
ON
(press LOCK)
Options: Lock with ignition
ON
only
(press UNLOCK)
Unlock with ignition OFF
only
(press TRUNK)
OFF
(press
•••
)
This feature will automatically lock the doors when the ignition key is turned on and/or unlock the
doors when the ignition key is turned off.