Application Precautions 5
Connecting or disconnecting the connectors
Before touching the Unit, be sure to first touch a grounded metallic object
in order to discharge any static built-up. Not doing so may result in mal-
function or damage.
Confirm that no adverse effect will occur in the system before attempting
any of the following. Not doing so may result in an unexpected operation.
Changing the operating mode of the PLC. (including the Startup Mode
setting)
Force-setting/force-resetting any bit in memory.
Changing the present value of any word or any set value in memory.
When replacing parts, be sure to confirm that the rating of a new part is
correct. Not doing so may result in malfunction or burning.
Resume operation only after transferring to the new CPU Unit and/or Spe-
cial I/O Units the contents of the DM and HR Areas required for resuming
operation. Not doing so may result in an unexpected operation.
When transporting the Units, use special packing boxes and protect them
from excessive vibration or shock during transportation.
Connect all communications cables within the limits given in the specifica-
tions.
Observe the following precautions when wiring communications cables.
Separate the communications cables from power lines or high-tension
lines.
Do not bend the communications cables.
Do not pull on the communications cables with an excessive force.
Do not place heavy objects on the communications cables.
Be sure to put the communications cables inside conduits.
Water-resistant Terminals used as Slaves are of IP67 construction. Do not
attempt to use the Watertight Terminals for applications where the Water-
tight Terminals are always underwater.
Install the Unit properly as specified in the operation manual. Improper
installation of the Unit may result in malfunction.