254
Connector Terminals Section 5-2
1,2,3... 1. Using an XG4A-4030-T MIL Connector (sold separately) to Assemble Your
Own Cable
For details, refer to MIL Connector Wiring and Assembly on page 258.
2. Connecting with OMRON Products Using an MIL-compatible Cables Man-
ufactured by OMRON
Select the MIL-compatible Cable from the following table according to the
Connector Terminals and I/O Block to be connected.
Note MIL-compatible cables are not provided as standard and must be ordered
separately.
The following cables are available, each of which is provided with a single MIL
connector for the Connector Terminal end.
Insert with protrusion facing right.
Slave model MIL-compatible Cable Connecting I/O block Remarks
SRT2-MD32ML G79-M50-25-D1 (50 cm)
G79-M75-50-D1 (75 cm)
Inputs:G7TC-ID16/IA16
Outputs:G7TC-OC08/OC16
G7OD-SOC16/VSOC16
G70A-ZOC16-3
Input and output wires can
be distinguished with the
following colors.
Inputs: Red
Outputs: Yellow
SRT2-MD32ML-1 G79-M50-25-D2 (50 cm)
G79-M75-50-D2 (75 cm)
Inputs:G70A-ZIM16-5
Outputs:G70A-ZOC16-4
G70D-SOC16-1
MIL-compatible cable Remarks
G79-A200C-D1 (2 m)
G79-A500C-D1 (5 m)
Wire dia.: AWG28 (other end)
All wires are precut.
G79-Y100C-D1 (1 m)
G79-Y200C-D1 (2 m)
G79-Y500C-D1 (5 m)
Fork terminals provided to other end.
Fork terminal: Nippon Tanshi’s 161071-M2