Revision History
07 October 2003 Additions and changes were made on the following pages:
Page xvii: Note added under table.
Page 2: Diagram changed to remove one of the terminators.
Page 3: Corrected “CIO 2000” to “CIO 2002” in third row of table for OUT data.
Page 6: Changed “CIO Area” to “I/O Area” in master characteristics.
Page 31: Moved diagram to preceding subheading.
Page 37: Changed order of symbol definitions for equations.
Page 53: Added information and diagram on mounting direction
Page 160: Swapped “V” and “G” terminals in specification for residual voltage,
and removed information on leakage current for specific models.
Page 172: Changed notes on COM terminals.
Pages 173, 174: Corrected dimension from “50” to “51” in diagram.
Page 193: Corrected “14” to “20.4” for I/O power supply voltage.
Page 215: Changed diagram for horizontal panel mounting.
Pages 254, 263, 264: Corrected dimension from “20” to “10” in diagram.
08 October 2005 "PC" was globally changed to "PLC" in the sense of "Programmable Controller."
Page xiv: Precaution added toward bottom of page.
Page xv: Precaution added toward top of page and precaution changed in mid-
dle of page.
Page xvi: First indented bulleted text changed.
Page 138 and 160: Input currents changed in table.
Page 157: New note 2 added.
09 August 2007 Added information on the CS1W-SRM21 Master Unit for CS-series PLCs to rel-
evant sections throughout the manual.
Deleted information on Bit Chain Terminals due to discontinuation of manufac-
turing.
Revision code Date Revised content