443
Analog I/O Units Section 7-4
0005
TIM
#0002
Always ON Flag
P_On
2
D0
T0005
MOV(021)
(P_EQ)
100.00
3
D1
T0005
MOV(021)
D10
102
T0005
MOV(021)
2
#8000
T0005
CMP(020)
Execution
condition
Execution
condition
Execution
condition
Execution
condition
← Reads analog input 1's of CP1W-MAD42 converted value.
← Reads analog input 2's of CP1W-MAD42 converted value.
6
D4
T0005
MOV(021)
7
D5
T0005
MOV(021)
Execution
condition
Execution
condition
← Reads analog input 1's of CP1W-MAD44 converted value.
← Reads analog input 2's of CP1W-MAD44 converted value.
Open-circuit detection (4-20 mA).
Open-circuit detection (4-20 mA).
← The content of D10 is written to the output
word as the analog output set value.
Open-circuit alarm
(P_EQ)
100.01
D12
104
T0005
MOV(021)
6
#8000
T0005
CMP(020)
Execution
condition
Execution
condition
← The content of D10 is written to the output
word as the analog output conversion value.
Open-circuit alarm