E3X-DAC-S
20
Bank input
Channel switch
Open
Set the SET/RUN Mode
Selector to SET.
(Factory-set to RUN)
Match
Increases threshold. Decreases threshold.
Threshold
Workpiece
The set condition
will flash twice.
Teaching with
Workpiece
Match Threshold
Match Threshold
Set the SET/RUN Mode
Selector to SET.
Press
either button
for 1 s.
Workpiece
The set condition
will flash twice.
Teaching with
Workpiece
The set threshold
will flash twice.
Match Threshold
Match Threshold
Match Threshold
Set the SET/RUN Mode
Selector to SET.
Teaching without
Workpiece
* Workpiece colors must always be taught to perform judgment for
registered workpiece colors.
* With the factory settings, 1-point teaching can be executed in RUN
mode. (Press the MODE Key for 3 s.)
Along with registering the workpiece colors, the threshold
can be set at approximately –10% of the match.
The setting is completed in a simple operation with one
press of a button.
Two points, with and without the workpiece, are detected,
and the match of the intermediate point is set as the
threshold value.
This method is ideal for setting thresholds with margins or
performing judgments with low match.
Press
either button
for 1 s.
Press
either button
for 1 s.
A threshold can be set manually. A threshold value can
also be fine-tuned using manual setting after teaching.
* Even if the display method for the Display Switch Function is
changed, the threshold will appear on the sub-display when the key
is pressed.
* Advanced Models
Set the Channel Selector to the desired channel before making any
adjustments or settings. This is true for all adjustments and settings.
OVER : Move the workpiece away.
OK : Teaching is possible.
LO : Move the workpiece closer.
* When teaching is performed, position the workpiece by using the
OVER, OK, and LO messages displayed on the sub-display (green)
as guides.
* The threshold level can be changed if the teaching level function is
used in SET mode.
* If BLACK mode is selected as the judgment mode in SET mode, the
threshold will be set to a level of approximately 10% higher than the
displayed degree of matching.
The operation mode is set with the Mode Selector.
* Advanced Models
The operation mode is set in SET mode.
Display
Closed
Bank
Open
Closed
A B C D
The bank where data is registered can be changed by using the bank input and the channel switch.
UP DOWN
L
D
RUN
UP DOWN
SET
RUN
RUN
UP DOWN
UP DOWN
SET
12 2 1 12 2 1
1
2
Operation mode Operation
Match ON
Mismatch ON
L-ON
D-ON
(Factory-set)
3
3-1. One-point Teaching
To RUN
4
To RUN
3-2. Teaching with and without the Workpiece
➜ Page 21 Refer to 5. Setting Functions in SET Mode.
Setting Thresholds Manually in RUN Mode
Registering Workpiece Colors with Teaching in SET Mode
Setting the Operation Mode
Changing Banks (for Advanced Models (4-color Determination))