E3X-MDA Super Dual Fiber Sensors 13
Coaxial Fiber Units
* Values are sensed for white paper (standard sensing object).
Side-view Fiber Units
* Values are sensed for white paper (standard sensing object).
Chemical-resistant Fiber Units
* Values are sensed for white paper (standard sensing object).
Features Appearance Applicable
Amplifier Unit
Sensing distance (mm)* Standard object
(min. sensing
object: Gold
wire)
Model Permissi-
ble bend-
ing radius
M6 coaxial; high-
precision positioning
E3X-MDA 500
×500
(0.005-mm dia.)
E32-CC200 25 mm
3-mm dia.; small di-
ameter; coaxial;
high-precision posi-
tioning
E3X-MDA 300
×300
(0.005-mm dia.)
E32-D32L
M3 coaxial; high-
precision positioning
E3X-MDA 100
×100
(0.005-mm dia.)
E32-C31
M3 coaxial; high-
precision positioning
E3X-MDA 50
×50
(0.005-mm dia.)
E32-C41
2-mm dia. coaxial;
high-precision posi-
tioning
E3X-MDA E32-C42
2-mm dia. coaxial;
high-precision posi-
tioning
E3X-MDA 100
×100
(0.005-mm dia.)
E32-D32
Features Appearance Applicable
Amplifier Unit
Sensing distance (mm)* Standard object
(min. sensing
object: Gold
wire)
Model Permissi-
ble bend-
ing radius
6-mm dia.; long dis-
tance
E3X-MDA 200
×200
(0.005-mm dia.)
E32-D14L 25 mm
6-mm dia. E3X-MDA 100
×100
(0.005-mm dia.)
E32-D14LR 1 mm
2-mm dia.; small di-
ameter; space-sav-
ing
E3X-MDA 50
×50
(0.005-mm dia.)
E32-D24 10 mm
E3X-MDA E32-D24R 1 mm
Features Appearance Applicable
Amplifier Unit
Sensing distance (mm)
*
Standard object
(min. sensing
object: Gold
wire)
Model Permissi-
ble bend-
ing radius
Fluororesin-cov-
ered; withstands
chemicals and harsh
environments (oper-
ating ambient tem-
perature:
−30°C to 70°C
E3X-MDA 200
×200
(0.005-mm dia.)
E32-D12F 40 mm
M6 screw
300
210
90
3-mm dia.
150
100
45
M3 screw
75
50
22
M3 screw
35
22
8
2-mm dia.
35
22
8
2-mm dia.
75
52
22
6-mm dia.
110
80
36
6-mm dia.
45
33
14
2-mm dia.
30
22
8
2-mm dia.
15
10
4
6-mm dia.
95
70
30