8 E3X-MDA Super Dual Fiber Sensors
Chemical-resistant Fiber Units
Features Appearance Applicable
Amplifier Unit
Sensing distance (mm)
(Parentheses: With E39-F1 Lens
Unit)
Standard object
(min. sensing
object)
(Parentheses:
Opaque object)
Model Permissi-
ble bend-
ing radius
Fluororesin-cov-
ered; round head
that resists water
drops
E3X-MDA 4-mm dia.
(0.1-mm dia.)
E32-T11F 4 mm
Fluororesin-cov-
ered; withstands
chemicals and
harsh environ-
ments
(operating ambient
temperature:
30°C to 70°C)
E3X-MDA 4-mm dia.
(0.1-mm dia.)
E32-T12F 40 mm
Fluororesin-cov-
ered; withstands
chemicals and
harsh environ-
ments; side-view
(operating ambient
temperature:
30°C to 70°C)
E3X-MDA 3-mm dia.
(0.1-mm dia.)
E32-T14F
Fluororesin; with-
stands chemicals
and harsh environ-
ments
(operating ambient
temperature:
40°C to 200°C)
E3X-MDA 1.0-mm dia.
(0.005-mm dia.)
E32-T81F-S 10 mm
7.2-mm dia.
1,600
1,300
520
5-mm dia.
2,600
2,000
800
5-mm dia.
320
250
100
6-mm dia.
600
460
190