18 E3X-MDA Super Dual Fiber Sensors
PNP Output
Note 1. Time Charts for Timer Settings (T: Set Time)
2. Control Output (AND, OR, Sync) and Time Chart for Timer Settings (T: Set Time)
Model Mode se-
lector
Timing chart State of
output
transistor
Output circuit
E3XMDA41
E3X-MDA8
LIGHT
ON
(L/ON)
Light ON
DARK ON
(D/ON)
Dark ON
CH1/
CH2
Incident light
No incident light
Operation
indicator (orange)
ON
OFF
Output
transistor
ON
OFF
Load (relay)
Operate
Release
(Between blue
and black)
Photo-
electric
Sensor
main
circuit
Brown
Black
Load
Control
output 1
Blue
12 to
24 VDC
Load
Control
output 2
Orange
Display
Operation indicator
(orange) ch 2
Operation indicator
(orange)
ch 1
CH1/
CH2
Incident light
No incident light
Operation
indicator (orange)
ON
OFF
Output
transistor
ON
OFF
Load (relay)
Operate
Release
(Between blue
and black)
ON delay OFF delay One-shot
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
Incident light
No incident light
T
CH1
CH2
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OUT
(sync)
OUT
(OR)
OUT
(AND)
T
CH1
CH2
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
(AND)
OFF delay
(AND)
ON delay
(AND)
T
T
T
One-shot