Control and Output in No-Protocol (TCP) / No-Protocol (UDP)
172
FQ2-S/CH User’s Manual
for Communications Settings
*1 The inspection results will be output according to the sorting method that is set for multi-point output for the inspection item.
Setting the Output Format
[In/Out] − [I/O setting] − [Output data setting] − [Noprotocol data output]
6 I0.Y[1] (Position Y 2nd point)
7 I0.SX[1] (Reference SX 2nd point)
8 I0.SY[1] (Reference SY 2nd point)
9 I0.X[2] (Position X 3rd point)
10 I0.Y[2] (Position Y 3rd point)
11 I0.SX[2] (Reference SX 3rd point)
12 I0.SY[2] (Reference SY 3rd point)
13 I0.X[3] (Position X 4th point)
14 I0.Y[3] (Position Y 4th point)
15 I0.SX[3] (Reference SX 4th point)
16 I0.SY[3] (Reference SY 4th point)
• In order to output multiple detection results of the inspection items that can be output their results simultaneously,
from the [Inspection] menu of the targeted inspection item, press [Multi-point output] and select [Yes].
1 Press [Output format].
2 Set [Output form] to [ASCII] or [Binary].
3 Set the data format for the data form that you select-
ed.
ASCII
Binary
Output order
*1
Assigned data
FQ2-S_CH_comm.book 172 ページ 2014年6月26日 木曜日 午前11時47分