Command Control
FQ2-S/CH User’s Manual
for Communications Settings
229
5
Appendices
* The communications protocol types are defined by the following numbers.
Acquire Communication Output Status
This command acquires the output status (allowed/prohibited) for all of the communications protocol set with
the Set Communication Output Status command.
Command (PLC to Vision Sensor)
Response (Vision Sensor to PLC)
Communications
protocol No.
Communications type Remarks
0 No protocol (Ethernet) No-protocol (UDP)
No-protocol (TCP)
No-protocol (FINS/TCP)
1 No protocol (RS-232C)
2 Parallel I/O
3 Fieldbus EtherNet/IP
PROFINET
4 Reserved Results in an error when speci-
fied.
5 PLC link PLC Link (SYSMAC)
PLC Link (MELSEC)
First word of com-
mand area
Bits Description
12 to 15 8 to 11 4 to 7 0 to 3
+2 0111 0000 0010 0000 Command code
+3 0000 0000 0010 0000
First word of
response area
Bits Description
12 to 15 8 to 11 4 to 7 0 to 3
+2 0111 0000 0010 0000 Command code
The command code for which the response
applies is stored.
+3 0000 0000 0010 0000
+4 0000 0000 0000 0000 Response code
Command execution result
0: OK, FFFFFFFF: NG
+5 0000 0000 0000 0000
+6 0000 0000 0000 0000 Acquired communications protocol status
0: Output prohibited status
1: Output allowed status
+7 0000 0000 0000 0000
FQ2-S_CH_comm.book 229 ページ 2014年6月26日 木曜日 午前11時47分